- Title
- Clinical validation of MR imaging time reduction for substitute/synthetic CT generation for prostate MRI-only treatment planning
- Creator
- Young, Tony; Dowling, Jason; Rai, Robba; Liney, Gary; Greer, Peter; Thwaites, David; Holloway, Lois
- Relation
- Physical and Engineering Sciences in Medicine Vol. 46, p. 1015-1021
- Publisher Link
- http://dx.doi.org/10.1007/s13246-023-01268-x
- Publisher
- Springer
- Resource Type
- journal article
- Date
- 2023
- Description
- Radiotherapy treatment planning based only on magnetic resonance imaging (MRI) has become clinically achievable. Though computed tomography (CT) is the gold standard for radiotherapy imaging, directly providing the electron density values needed for planning calculations, MRI has superior soft tissue visualisation to guide treatment planning decisions and optimisation. MRI-only planning removes the need for the CT scan, but requires generation of a substitute/synthetic/pseudo CT (sCT) for electron density information. Shortening the MRI imaging time would improve patient comfort and reduce the likelihood of motion artefacts. A volunteer study was previously carried out to investigate and optimise faster MRI sequences for a hybrid atlas-voxel conversion to sCT for prostate treatment planning. The aim of this follow-on study was to clinically validate the performance of the new optimised sequence for sCT generation in a treated MRI-only prostate patient cohort. 10 patients undergoing MRI-only treatment were scanned on a Siemens Skyra 3T MRI as part of the MRI-only sub-study of the NINJA clinical trial (ACTRN12618001806257). Two sequences were used, the standard 3D T2-weighted SPACE sequence used for sCT conversion which has been previously validated against CT, and a modified fast SPACE sequence, selected based on the volunteer study. Both were used to generate sCT scans. These were then compared to evaluate the fast sequence conversion for anatomical and dosimetric accuracy against the clinically approved treatment plans. The average Mean Absolute Error (MAE) for the body was 14.98 ± 2.35 HU, and for bone was 40.77 ± 5.51 HU. The external volume contour comparison produced a Dice Similarity Coefficient (DSC) of at least 0.976, and an average of 0.985 ± 0.004, and the bony anatomy contour comparison a DSC of at least 0.907, and an average of 0.950 ± 0.018. The fast SPACE sCT agreed with the gold standard sCT within an isocentre dose of -0.28% ± 0.16% and an average gamma pass rate of 99.66% ± 0.41% for a 1%/1 mm gamma tolerance. In this clinical validation study, the fast sequence, which reduced the required imaging time by approximately a factor of 4, produced an sCT with similar clinical dosimetric results compared to the standard sCT, demonstrating its potential for clinical use for treatment planning.
- Subject
- MRI-only; sCT; prostate; radiotherapy; SDG 3; Sustainable Development Goals
- Identifier
- http://hdl.handle.net/1959.13/1493279
- Identifier
- uon:53527
- Identifier
- ISSN:2662-4729
- Rights
- x
- Language
- eng
- Reviewed
- Hits: 1396
- Visitors: 1395
- Downloads: 0
Thumbnail | File | Description | Size | Format |
---|